The Freedom24 range has been specifically designed to meet the
requirements of Building Regulations Document H1 Foul Drainage.
This regulation recognises the need for pump stations to have a
24hr storage capacity in case of a disruption in service (such as a
power failure).
This comprehensive range offers an advanced solution to larger
domestic and industrial applications. For large-capacity flows (such
as stormwater run-off from hard-standing areas), horizontal holding
chambers are available in a comprehensive range of sizes.
- High-level alarm fitted as standard
- Various invert depths
- Internal lifting chains and guiderails fitted as standard
- Wide range of pump options including grinders/macerators
- Combined chamber capacity of up to 90,000 litres
- Pumping distances up to 1000 metres
- Pedestrian duty cover
- Lockable manhole cover
24hr Storage to Meet Building Regulations
The Titan Freedom24 pump station range has been designed in accordance with
Building Regulations Document H1 Foul Drainage, page 16. (Pumping Installations)
Section 2.39. This states: [read more...]
Where foul drainage from a building is to be pumped, the effluent
receiving chamber should be sized to contain 24 hour inflow to allow for
disruption in service. The minimum daily discharge of foul drainage should
be taken as 150 litres per head per day for domestic use. For other types of
building, the capacity of the receiving chamber should be based on the
calculated daily demand of the water intake for the building. Where only a
proportion of the foul sewage is to be pumped, then the capacity should be
based pro-rata. In all pumped systems the controls should be so arranged
to optimise pump operation. The required 150 litres per head per day
volume should reflect the storage volume in the station pump or station and
overflow tanks.

Pump Chamber Selection
Click here to expand
New for 2008, Titan’s renowned
Freedom series is joined by the Mini
and Micro compact pump stations.
Designed for rapid installation, the
chambers provide simple and speedy
dewatering of buildings and areas below
the sewer level and are suitable for
pumping wastewater in accordance
with DIN/EN 12056.
Applications
- Outbuildings and extensions
- Cellars
- External WCs
- Pool houses
Chambers are suitable for effluent and
sewage dependent on pump specification,
required distance and lift.
Specification
| Mini |
690 |
720-920 |
340 |
350 |
100/150 |
63 |
| Micro |
530 |
670-800 |
340 |
350 |
100 |
50 |
Design
All Freedom Mini and Micro systems
consist of a polyethylene chamber
fitted with a quality pump, float switch,
non-return valves, pedestrian duty
cover and frame, cover plate and all
connections.
Features
- Ready for simple and immediate installation
- Fully adjustable for height and floor level alignment
- Non-return valves as standard
- Protective cover for protection during installation
- Manufactured from tough polyethylene
- Corrosion resistant
- Outlet pipe compression fittings as
standard
Installation & Operation
The access neck and cover are universally
adjustable in height and can be rotated to
allow easy alignment with flooring and
landscaping design, independent of the
inflow or discharge line directions.
A protective cover for the access neck is
supplied for use during installation to prevent
backfill from damaging the access cover.
Access neck extension piece is available as
part of the package to facilitate a further
150mm inlet depth if required.
Sewage Pump Performance Mini (40mm solids handling)

Effluent Pump Performance

Click here to read more...
|